Injury Illness Prevention Plan - Flipbook - Page 141
Health and Safety Program Manual
Teamwrkx
Construction, Inc.
Issue Date: 10/16/23
Revision Date: 10/16/23
Hot Work
Reference: A-9
Oxweld 63
Copper, Ozone
98% Copper
B
Copper, Ozone
Airco 110
98% Copper
B
Oxweld 62
Copper, Ozone
B
91.5% Copper, Aluminum
18% Chromium, 13% Nickel, Steel
B
Type 316 Stainless
Copper, Nickel, Ozone
Aluminum
B
Aluminum
Ozone
B
Nickel, Molybdenum
Hastelloy B
Nickel, Ozone
Chromium, Nickel
B
Inconel 62
Nickel, Ozone
B
Iron
Oxweld 65
*High levels of ultraviolet light produced. Avoid eye flash with side shield goggles. Avoid skin burns with
proper clothing.
B. Moderate amounts of fumes generated:
1. Use exhaust blowers or air siphons to remove fumes from breathing zone in open areas.
2. Work in confined spaces or poorly ventilated areas will require high efficiency particulate
respirators.
Acetylene Welding and Brazing
Wire
Hastelloy D
Oxweld 5M
1 Oxweld
Aluminum
Everdur 1010
Arcosil J
Oxweld 28
18-8 Stainless
Easy-Flo
Sil-Fos
Oxweld 372
Colmonoy 6
Chromium
Stoodite
Borod
Basic Elements
Silicon, 90% Nickel
Copper, Zinc, Tin
Steel
Aluminum
Copper, Silicon
56% Silver, 22% Copper
17% zinc, 5% Tin
18% Chromium, 8% Nickel, Steel
18% Chromium, 8% Nickel, Steel
45% Silver, 15% Copper
25% Cadmium, 16% Zinc
15% silver, 80% Copper
5% Phosphorus
98% Copper
65% Cobalt, 28% Chromium
Tungsten
Iron, 30% Chromium
Tungsten Carbide, Iron
Harmful Byproducts
Nickel
Copper, Zinc
Copper
Copper, Zinc
Precautions
A
B
A
A
A
B
Chromium, Nickel
Chromium, Nickel
Copper, Cadmium
Zinc
Copper
B
B
B
Copper
Cobalt, Chromium
B
B
Chromium
B
B
A. No special precautions are needed in open or well-ventilated areas. Work in confined spaces or
poorly ventilated areas may require fume filter-type respirators. Consult the mechanical welding and
metals supervisor.
B. Moderate amounts of fumes generated:
11